Administrator Only Special Functions (cont):
Power Loss Report:
The unit is able to send alert message to the administrator in the event the main power is out / turned off. When the main power is
restored it can notify the administrator again the main power is on.
When main power OFF
The unit will send a message: ACP-OFF
Note: At the same time, it will send an ALWAYS high pulse out from I/O port. Alarm will sound.
When main power restored
The unit will send a message: ACP-O
__________________________________________________________________________________
Intercom Volume:
It is possible to adjust the volume (from level 1 to 6) of the intercom by sending the following SMS command. Factory Default:
4
Example: Sending the following SMS Command
*SOUD#5 – Adjust the volume to 5
Example of Returned Message:
SOUD:<5>
__________________________________________________________________________________
Microphone Volume:
It is possible to adjust the volume (from level 1 to 9) of the intercom by sending the following SMS command. Factory Default:
2
Example: Sending the following SMS Command
*MIC0#5 – Adjust the volume to 5
Example of Returned Message:
MIC0:<5>
OTE: after the C in the above SMS command it is a ZERO, not an O