Alternate Relay Activation (cont):
Temporary longer latch:
You can extend the time the gate pauses in the open position by extending the relay latch time for a single
use. This is helpful if you are driving a slow moving or long vehicle. It can be held for up to 65000 seconds.
Via phone call:
Once the call has connected… (With a short beep ~ prompt the administrator to enter password, the initial set up password is
123456 by default)
After enter password… (Another short beep ~ Password Correct)
Press *6# (A short beep ~ success)
Continue press 1# for relay 1 (A short beep ~ success)
Then input value 00030# (A short beep ~ success)
Relay 1 will now latch for 30 seconds and after 30 seconds it will switch off and sends a message back to the administrator in-
formed that Relay 1 has closed.
Via text message (SMS):
Example:
Temporary latch Relay 1 for 60 seconds or
Temporary latch Relay 2 for 180 seconds
Simply send either of the 2 SMS command as below:
*RLY1#00060
*RLY2#00180
Example of Returned Message:
RELAY1=00060
RELAY2=00180